The installation must be compliant with the IET Wiring Regulations and the IET Code of Practice for Electric Vehicle Charging Equipment. Installation should be carried out by a competent electrician with appropriate knowledge of EV charge point installations.

Step 1

u003cp data-renderer-start-pos=u00227043u0022u003eThe Ohme Home Pro is designed to be wall mounted to a flat surface. Fixings are included which are suitable for most wall surfaces (e.g. brick/render) but the installer should select their own fixings if these are not appropriate.u003c/pu003ernu003cp data-renderer-start-pos=u00227275u0022u003eAttach the back plate to the wall using the four fixings supplied.u003c/pu003e

Step 2

Mount the unit, carefully guiding the three lugs into the rear of the unit.

Step 3

u003cp data-renderer-start-pos=u00228474u0022u003eUse the supplied three M4 short machine screws to fix the unit to the back plate.u003c/pu003e

Step 4

u003cp data-renderer-start-pos=u00227554u0022u003eThe Ohme Home Pro is supplied with a one metre fixed input cable/flying lead requiring termination on-site to a suitable junction box, isolation switch, or mini-CU (not supplied). The flying lead conductors are 6mm2 copper, the overall diameter is 15.2mm, suitable for a No. 6 cable cleat.u003c/pu003ernu003cp data-renderer-start-pos=u00227845u0022u003eTo connect, typically an installer will either:u003c/pu003ernu003cp data-renderer-start-pos=u00227894u0022u003e·  Install a junction box at ankle heightrn·  Feed the input cable through a wall and terminate on the other sideu003c/pu003ernu003cp data-renderer-start-pos=u00228009u0022u003eu003cstrongu003eNote: The junction box needs to be rated to at least 32A, have sufficient IP rating for the location, and have space for a three-way terminal block (no load balancing) or five-way terminal block (with load balancing).u003c/strongu003eu003c/pu003e

Step 5

u003cp data-renderer-start-pos=u00228239u0022u003eThe Ohme Home Pro has a dynamic load-balancing feature. A current sensor (CT) clamp is provided to measure the electrical demand of the property, or sub-board. The unit will limit the maximum current available to the vehicle to keep the household demand below the set threshold/fuse value.u003c/pu003ernu003cp data-renderer-start-pos=u00228530u0022u003eWhere load balancing is activated, if the CT clamp is removed, installed in the wrong location or is faulty, the unit will revert to charge at a maximum of 16A. It is therefore sensible to ensure the spare capacity, after taking account of other loads and diversity, is at least 16A.u003c/pu003e

Step 6

u003cp data-renderer-start-pos=u00228832u0022u003eThe charger comes complete with a cable holder and charging gun holster to retain the cable and vehicle connector when not connected to the vehicle. Use a further four fixings to mount these to the wall.u003c/pu003ernu003cp data-renderer-start-pos=u00229037u0022u003eOnce the charger is installed and connected to power it will turn on and be ready for commissioning.u003c/pu003e

Storage while not in use

u003cp data-renderer-start-pos=u00229174u0022u003eWhen the charger is unplugged from the vehicle it must be stowed away correctly.u003c/pu003ernu003cp data-renderer-start-pos=u00229256u0022u003eWrap the cable around the cable holder.u003c/pu003ernu003cp data-renderer-start-pos=u00229297u0022u003eThe charger plug must be pushed into the holster, you will hear a click when it is locked in place. This protects the charging pins from the elements. Push the button on the top of the holster to release the charging plug.u003c/pu003e

Installation complete

Now that you’ve successfully installed the Ohme Home Pro, check out the following article for how to commission an Ohme charger.